Part Number Hot Search : 
LD105 AE10737 PT22B4 RATION 2000W 30120 2SD88205 17D06
Product Description
Full Text Search
 

To Download AXHV2001 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Issue: 01 Specification AXHV2001 Oscillator type : VCO - Voltage Controlled Oscillator
Date: 2005-12-08
Parameter
min.
typ.
max.
Unit
Condition
1800 2900 MHz @ 25C Frequency tuning range Frequency adjustment range EFC voltage VC 0.2 15 V positive EFC slope (f / VC) RF output Signal waveform SINUS Amplitude +4 +6 dBm RL = 50 -90 dBc/Hz @ 100 kHz Phase Noise Supply voltage VS 4.75 5 5.25 V Current consumption (steady state) 15 mA -10 +60 C Operating temperature range -20 +70 C Operable temperature range -40 +85 C Storage temperature range 12.7 x 12.7 x 6.1 mm Enclosure (see drawing) LxWxH 5 gram Weight bulk IEC 60286-3 Packing 1500 V HBM, IEC 61000-4-2 ESD Sensitivity Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated
Ordering Code:
Model (Specification) AXHV2001 Frequency Range [MHz] 1800-2900
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXHV2001 page 1(3)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
Enclosure drawing
Pin connections
Pin # Symbol P1 VC P2 RF OUT P3 VS P4 N.C. All GND others Function Control Voltage (EFC) RF Output Supply Voltage Not Connected Ground
Typical Performance
HV2001 VCO 1.8 GHz bis 2.9 GHz
fres/GHz 3 2.8 2.6 2.4 2.2 2 1.8 1.6 0
5V/15mA Phase Noise: <-90dBc/Hz in 100kHz
5 Vtune/V
10
15
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXHV2001 page 2(3)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com
Pout/dBm 10
HV2001 VCO 1.8 GHz bis 2.9 GHz
8
6
4
2
0 0 5 Vtune/V 10 15
Environmental conditions
Test Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* Bump* Free fall* IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.2 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 5)C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days
2-17 2-20 2-58 2-27 2-29 2-32
4.6.8 4.6.6 4.6.9 4.6.7
Vibration, sinusoidal* 2-6
Rapid change of temperature Dry heat Damp heat, cyclic* Cold Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging
2-14 2-2 2-30 2-1 1-7 2-3
4.6.5 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18
4.7.1 4.7.2
30 days @ 85C, OCXO @25C 1000h, 2000h, 8000h @85C
GmbH & Co. KG Wasemweg 5 D-74821 Mosbach Germany
AXHV2001 page 3(3)
www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com


▲Up To Search▲   

 
Price & Availability of AXHV2001

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X